-40%

Dental X Ray Portable Mobile Film Imaging Machine BLX-5 Digital Low Dose System

$ 233.37

Availability: 36 in stock
  • Return shipping will be paid by: Seller
  • Shipping notice: Can not ship to Puerto Rico/Alaska/Hawaii
  • Refund will be given as: Money Back
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • All returns accepted: Returns Accepted
  • Brand: Unbranded
  • Restocking Fee: No
  • Condition: New
  • Voltage:: 110v±10%
  • Item location:: CA /NJ /Austell
  • Rating:: 60W
  • Frequency:: 30 KHz
  • 2. Power:: 24V 8000MA

    Description

    Store category
    Sign Up Now !
    You may also like
    Dental X Ray Portable Mobile Film Imaging Machine Digital Low Dose System BLX-5
    Product Description
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).
    Th
    e tube voltage frequency of this machine is 30 KHz

    and the tube current is 0.1 M
    A.
    The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    All the components of this product were originally imported to achieve an acceptable tolerance required for the digital controls and the machine. By doing this

    product perform ance is more stable and reliable.
    Using a Toshiba 0.3
    x
    0.3 micr
    o-
    focus tube

    the image is clearer and more delicate. This machine uses components from well established suppliers

    allowing us to deliver to our customers a product of high quality.
    There are films included for testing purpose and all the consumables can be replaced by other similar products.
    There are vacuum components and high-pressure parts inside of the machine

    so for your safety and the maintenance of the machine

    please do not open the machine. Service and maintenance should only be performed by a trained professiona
    l.
    The tube head is equipped with excellent radiation-shield protection (except the radial mouth

    and tests have shown that the radial index is zero. Safety is guaranteed.
    Non-film inspection and storage can be realized when corresponding to a sensor.
    TECHNICAL SPECIFICATIONS

    1.
    Voltage: 110v±10%
    2.
    Power: 24V 8000MA
    3.
    Charger: 110V, 60Hz
    4.
    Tube current: 0.1mA
    5.
    Rating: 60W
    6.
    Frequency: 30 KHz
    7.
    Exposure time: 1-9 seconds optional
    8.
    Leak radiation: < 20μgy/h(12lb)
    9.
    Focus Skin Distance: >20cm
    10.
    Tube voltage: 60KV
    11.
    Relative Humidity(RH) < 80%
    12.
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    13.
    Net weight: 5.5 kg
    14.
    Dimension: 47 x 42 x 19 cm
    The Angle should be proper while taking a picture. The film should be put vertically behind the tooth to be taken a picture while the case is for the front teeth; and the film should be put transversely
    behind the tooth to be taken a picture while the case is for the back teeth. The patient should use forefinger to press the film behind the tooth gently.
    *Kodak film as the sent samples are strongly recommended.
    Reference of the Angles
    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure
    Tooth
    Adult
    Child
    Central
    &
    Lateral
    2.5-3.25
    2-2.7
    Cuspid
    &
    1
    st
    Bicuspid
    3.2
    -4
    2.7-3.5
    Upper 5

    6
    3.5
    -4
    3-3.5
    Upper 7

    8
    7.5-8
    7-7.5
    Lower 5

    6
    4
    -4
    .5
    3.5
    -4
    Lower 7

    8
    4
    -4
    .5
    3.5
    -4
    Operation of the Main Unit
    1.
    Upon receiving

    open the box and check the product for possible damage during shipping.
    2.
    Make sure the fittings on the encasement list are packaged within the box.
    3.
    Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw; Install the blue ray tube to the foreside of the ball head

    then tighten it.
    4.
    After the Main Unit and ball head are perfectly fit together

    plug in the international standard electrical source

    grounding is strongly recommended.
    5.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
    6.
    Setting the time
    (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode

    then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    7.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    8.
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    9.
    After positioning

    use the ON/OFF on the main Unit

    the remote controller

    or the button on the touch head tube to take pictures. The three methods have the same effec
    t.
    (Notice: gently press 0.5 sec to turn it on)
    10.
    After exposure to the tube

    press the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    11.
    Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.
    12.
    Turn the power of the main unit off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the main unit long in standby mode.
    Developing the Dental film
    1.
    Picture the tooth following the right operating procedure of the X-ray Unit

    then take the film out from the mouth.
    2.
    Use a syringe to extract 4-5 mi of imaging liquid.
    3.
    Transfuse the liquid into the bag

    nip both the ends and the sides of the bag with thumbs and first fingers(knead the film).
    4.
    Open the end of the bag about ten minutes after transfusing the liquid into the bag.
    5.
    Take the film out

    put it into clear water

    and rinse i
    t.
    Don't wipe the surface of the film with the surface to prevent damage to the image.
    6.
    Observe and diagnose after the film becomes dry.
    Packing
    Li
    st:
    1.
    Main Unit
    2.
    Ball Head
    3.
    2 cables
    4.
    Blue tube
    5.
    Other accessories
    Payment
    Delivery details
    Feedback
    Return policy
    Contact us
    Payment
    We accept PayPal payment only
    Payment must be received within 7 days after order is made.
    Fees such as import duties, taxes are not included in the item price or shipping costs. These charges are the buyer's responsibility.
    Delivery details
    Shipping:
    The item will be shipped from our US warehouse to United States, which is more faster than from aboard.
    2-9 working days to: USA
    Feedback
    We maintain high standards of excellence and strive for hundred percent customer satisfaction. Feedback is very important to us. We hope that you contact us immediately before you give neutral or negative feedback, so that we can address your concerns. It is impossible to address issues if we do not know about them!
    Return policy
    Your satis
    faction is our ultimate goal. We work hard to earn your trust and future business. Our certified technicians have tested each item before shipping. The unit comes with 1 year limited warranty on all manufacturing defects.
    a) If you receive a defective item, you may return it or ask for a discount. Please contact us within 14 days after you receive the package.
    b) What you returned must be intact and in its original packaging as re? u. Customer is responsible for shipping costs of the returned item.
    c) We will cover the cost of shipping back t with the shipping rate indicated in the registration page. We will send you a new unit or refund the full payment you paid.
    Thank you.
    Contact us
    Business Hour
    Business Hour: Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)
    Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.
    Please contact us with ebay message.
    Please feel free to contact us if you have any questions.
    : Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)
    Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it's non-workdays, please kindly be patient and wait till Monday.
    Please contact us with ebay message.
    Please feel free to contact us if you have any questions.
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).The tube voltage frequency of this machine is 30 KHz,and the tube current is 0.1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine." All the components of this product were originally imported to achieve an acceptable tolerance required for the digital controls and the machine. By doing this, product perform ance is more stable and reliable. Using a Toshiba 0.3 x 0.3 micro-focus tube, the image is clearer and more delicate. This machine uses components from well establ
    On Jan-01-20 at 17:46:05 PST, seller added the following information: